Paper Tape Wear Tester Surface Coating Abrasion Detector RCA Scroll Tape Abrasion Testing Machine for Laboratory

Test Weight (g)
55, 175, 275
Overall dimensions
830×490×340mm
Power supply
1‑Phase, 220V, 5A (or as specified)
Weight
20kg
Standard configuration
A set of tools. A magnifying glass. Test load: 55g, 175g each. Three O-rings. 1 roll of paper tape


Telephone:+86 13018663273 Mail:carleen@sailham.com

Detail

Feature Description

1 This machine is driven by a specially‑designed micro‑motor, coupled with synchronous belt transmission, ensuring smooth operation and low noise. 2 Multiple clamping fixtures ensure accurate and reliable test results. 3 Digital display counter to directly show test cycles.

Instructions for Use

1  The instrument must be placed on a stable table before use; 2  It is not allowed to move the machine during use; 3  Choose the corresponding power supply voltage, do not exceed it to avoid burning out the components; 4  In case of any abnormality in the instrument, please contact our office for timely handling; 5  The machine must have a good ventilation environment during operation. 6  Due to the high operating load, please add lubricating oil to the mechanical components of the button machine in a timely manner; 7  After each experiment, clean the machine and keep it clean; 8  The control box should be wiped with a dry cloth and not with a damp cloth.Packing ListHost.  set of tools. A magnifying glass. Test load: 55g, 175g each. Three O-rings. 1 roll of paper tape.

1.jpg

Purpose/Application Field/Attention

Suitable for wear resistance testing of mobile phones, PDAs, MP3 players, CD players, laptops, and various surface coating samples. 1 If there is no display when the power is turned on, it means that the power is not turned on or the power indicator light is damaged. If the power indicator light is damaged, replace it. If there is no power output from the power output terminal, please check the power cord or powered socket. 2 If the power is turned on and the power indicator light indicates that the machine is not working when the start button is pressed, please check whether the relay is disconnected or disconnected. If it is disconnected or disconnected, please connect it in time. If the relay is not disconnected or disconnected, it indicates that the relay is damaged and should be replaced in a timely manner. 3 If the motor still does not stop working after reaching the set number of times in the counter, it indicates that: (1) The counter is damaged;; (2) After setting the counter multiple times, the reset button is not pressed to write. 4 If the power indicator light is on and the counter does not display, it indicates that the counter is damaged and needs to be replaced.