position:   Home  >   Product  >   Salt spray test chamber

ZH-TSH-60A / 90A / 120A Cyclic Corrosion Test Chamber

Cyclic Corrosion Test Chamber 

ZH-TSH-120A 

1650517636(1).png

Model

ZH-TSH-120A

Sample limited

The test equipment prohibits the testing of flammable, explosive and volatile substances; the test and storage of corrosive substances, biological tests, strong electromagnetic emission sources etc..

Volume, weight and size

Nominal volume

600 L (other volume models are available)

Inner size

1200×600×500 (mm)      W×D×H  (other size models are available)

External size

2150×1150×1350 (mm)  appr.   W×D×H

Weight

340 kg

Working noise

≤ 75db measured in the air, 1 meter from the front of the machine and 1.2 meters from the ground

Power max.

9KW

Current max.

15A

 

 

Power supply

· AC380V three-phase four-wire + protective grounding

· Voltage permissible fluctuation range: ± 10% V

· Frequency permissible: (50 ± 0.5) HZ

· TN-S power supply or TT mode power supply

· Protection ground wire grounding resistance is less than 4Ω

· Requires the user to configure the appropriate capacity of the air or power switch for the equipment, and this switch must be independently controlled for the device.

Performance

Functional requirements

1) (air) indoor space heating, humidification, dehumidification, spraying, defogging;

2) To reach the set temperature, humidity, spray in the chamber according to the parameters set;

3) Each function can be operated independently.

Meet the test standards - Test Methods

GB/T20854-2007/ISO14993-2001 Wet and dry salt spray test

GB-T5170.8-2008 Electrical and electronic products environmental test equipment inspection methods - salt spray test equipment

JJB150.11A-2009 - Military equipment laboratory environmental test method - Salt spray test

GBT2424.17-2008 Test Method for Salt Spraying

GB / T 2423.18-2000 Test method for alternating salt spray of sodium chloride

GB-T2423.3-2006 (IEC6008-2-78-2001) Test cab: Constant damp heat test method

GBT2423_4-2008 Test method for heat and moisture alternating test

Temperature and humidity range (climate test)

Temperature and humidity range

Temperature range: 20 ℃ ~ 85 ℃ adjustable

Humidity range: 30% ~ 98% R.H 

1650517815(1).jpg

Control precision

Temperature resolution: 0.01 ;  Humidity resolution: 0.1% R.H.

Temperature deviation: ± 1.0 ;  Humidity deviation: ± 2% R.H.

Temperature uniformity: ± 2 ;   Humidity uniformity ± 3% R.H.

Temperature fluctuation: ± 0.5 ;  Humidity fluctuation: ± 2% R.H.

Heating rate

RT → +85 ≤ 60 min

Test conditions

This machine complies with test method: salt spray test → hot air forced drying test → humidity test

A) Salt spray laboratory: NSS, ACSS, CASS

Chamber temperature: 2 ~ 85  can be set (salt spray corrosion test 35  ± 1  / 50  ± 1 )

Pressure barrel temperature: 47  ± 1  / 63  ± 1 

Spray volume of 1.0 ~ 2.0 m1 / 80cm² / h (at least 16 hours to collect, take the average)

Relative humidity: 30% ~ 98% R.H.

Salt concentration: 5% or 5% concentration plus 0.26 g copper chloride (CuCl2 2H2O)

Spray pressure: 1.00 ± 0.01kgf / cm²

PH: Neutral test 6.5 ~ 7.2;  Acid test 3.0 ~ 3.3

Test plate installation angle: 15 ° ~ 30 °

B) Hot air drying test (DRY):

(1) Temperature: 60 °± °C

(2) Humidity: RH30%

(C) Humidity test (SOAK):

(1) Temperature: 50 °± °C

(2) Humidity: 95% RH or more